  • If so, it’s possible that the ice maker auger, a crucial component responsible for delivering water to the ice maker mold, might be the culprit.
  • Remove the ice bin from the ice maker module to gain clear access to the auger.
  • Carefully remove the screws or release the clips to detach the cover from the ice maker module.

Are you facing a frustrating situation where your GE ice maker is no longer producing ice, leaving you with an empty ice bin? If so, it’s possible that the ice maker auger, a crucial component responsible for delivering water to the ice maker mold, might be the culprit. This comprehensive guide will provide you with step-by-step instructions on how to replace the GE ice maker auger WR17X11939, empowering you to tackle this repair project with confidence.

Tools and Materials Required

Before embarking on this repair journey, ensure you have the necessary tools and materials at hand:

  • Replacement GE Ice Maker Auger WR17X11939: Purchase a genuine GE replacement part to ensure compatibility and optimal performance.
  • Screwdriver Set: A set of screwdrivers, including both Phillips and flathead, will be required to disassemble and reassemble the ice maker components.
  • Pliers: A pair of pliers will come in handy for removing and installing the ice maker auger.
  • Flashlight: A flashlight will be useful for illuminating dark and hard-to-reach areas during the repair process.
  • Shop Towels or Rags: Keep a few shop towels or rags nearby to wipe up any spills or clean components during the replacement.

Safety Precautions

Before commencing the repair, remember to take these safety precautions:

  • Unplug the Refrigerator: Always unplug the refrigerator from the power outlet before starting any repair work to prevent electrical hazards.
  • Turn Off the Water Supply: Locate the water supply valve connected to the refrigerator and turn it off to prevent water leakage during the repair.
  • Wear Protective Gear: Wear safety glasses and gloves to protect yourself from sharp edges or potential water splashes.

Step-by-Step Guide to Replacing the GE Ice Maker Auger WR17X11939

Follow these detailed steps to successfully replace the GE ice maker auger WR17X11939:

1. Access the Ice Maker Module

  • Open the freezer door and locate the ice maker module. It is typically situated at the back of the freezer compartment.
  • Remove the ice bin from the ice maker module to gain clear access to the auger.

2. Remove the Ice Maker Cover

  • Identify the screws or clips securing the ice maker cover.
  • Carefully remove the screws or release the clips to detach the cover from the ice maker module.

3. Locate and Remove the Old Auger

  • Once the cover is removed, you will see the ice maker auger.
  • Use the pliers to grasp the old auger and gently pull it out of its housing.

4. Clean the Auger Housing

  • Take this opportunity to clean the auger housing using a damp cloth.
  • Ensure that there is no ice buildup or debris obstructing the auger’s movement.

5. Install the New Auger

  • Align the new auger with the housing and carefully insert it into place.
  • Use the pliers to firmly secure the auger in its housing.

6. Reattach the Ice Maker Cover

  • Realign the ice maker cover with the module and secure it using the screws or clips you removed earlier.
  • Ensure that the cover is properly seated and there are no gaps.

7. Reconnect the Water Supply and Power

  • Locate the water supply valve and turn it back on to restore water flow to the ice maker.
  • Plug the refrigerator back into the power outlet to power up the appliance.

Testing the Replaced Auger

Once the repair is complete, perform a test run to ensure the ice maker is functioning properly:

  • Press the ice maker button on the control panel to initiate ice production.
  • Observe the ice maker for a few minutes toを確認 that it is delivering ice into the bin.

Wrap Up: Enjoying a Smooth-Running Ice Maker

By following this comprehensive guide, you have successfully replaced the GE ice maker auger WR17X11939, restoring your ice maker to its optimal ice-producing condition. Remember to regularly maintain your refrigerator and ice maker to prevent future issues and enjoy a continuous supply of fresh, cold ice.

Answers to Your Questions

Q1: Can I use a generic ice maker auger instead of the GE-specific WR17X11939?

A: Using a generic auger may compromise the performance and longevity of your GE ice maker. It is recommended to use the genuine GE replacement part to ensure compatibility and optimal results.

Q2: How often should I clean the ice maker auger and housing?

A: Regular cleaning of the ice maker auger and housing is essential to prevent ice buildup and ensure smooth operation. Aim to clean these components every 6-12 months, or more frequently if you notice reduced ice production or other issues.

Q3: What other maintenance tasks should I perform to keep my GE ice maker in top condition?

A: To maintain the longevity and performance of your GE ice maker, consider the following maintenance tasks:

  • Clean the condenser coils located at the back or bottom of the refrigerator to ensure proper heat dissipation.
  • Replace the water filter every 6 months or as recommended by the manufacturer to ensure clean water supply to the ice maker.
  • Regularly inspect the ice maker for any signs of wear or damage, and address any issues promptly.